3 CONNECTION TRACING
Assuming you have successfully completed all the configuration checks in the previous
section - on your network, we’ll now trace the path of a session, starting at the
originating point of the call. In the command sequence shown, the configuration from
the previous section is still being used. To aid in troubleshooting your actual network,
print out the network diagram in Appendix B, which should be very similar to the
topology of your network. Fill in the blanks to get a diagram of your configuration, which
can be used for reference and noting results from these troubleshooting steps.
3.1 Step 1 - Check IP Network Connectivity
From the DT-6061 console, ping the client PC and the UMI, using the
diag ping <IP
Address>
command, to verify network connectivity. If both respond, proceed to Step 2.
If there is no response in either case, examine the IP network for possible faults. Are the
physical connections (cables, hub port) ok? Are the correct gateways and sub-net masks
configured?
3.2 Step 2- Find Remote TCP Port Associated with Client
From the DT-6061 console, run the
diag addr <client PC address> 0
command. This
report will display all connected sessions associated with the client PC’s IP address.
<DT-6061> diag addr 192.168.1.160 0
Instance=2 type=tn3270 FD=6 IP=192.168.1.160.2385
The report shows that the client PC is connected to the TN3270 application assigned to
instance number 2. The TCP port used by the client software (2385) is shown in addition
Vue de la page 11