DT-6061 User's Manual - Platform (Build 17.1)
12/14/09
Datatek Applications Inc. 58
10.3 UDP
–
DM UDP
<DT-6061> dm udp
udp:
834716 datagrams received
UDP 1 0 with incomplete header
UDP 1 0 with bad data length field
UDP 1 0 with bad checksum
UDP 2 1 dropped due to no socket
UDP 2 189454 broadcast/multicast datagrams dropped due to no socket
UDP 1 0 dropped due to full socket buffers
645262 not for hashed pcb
UDP 3 645261 delivered
UDP 4 570930 datagrams output
Measurement descriptions:
UDP 1: The number of received UDP datagrams that could not be delivered, broken down by
reasons other than the lack of an application at the destination port.
UDP 2: The number of received UDP datagrams for which there was no application at the
destination port.
UDP 3: The total number of UDP datagrams delivered to UDP users.
UDP 4: The total number of UDP datagrams sent from this entity.